Control units for continuous lighting
Brief product information
The units are microcontroller-based and specially designed to be compatible with all types of LATAB lighting.
This is thanks to a plug-and-play function that automatically adjusts/limits the current to the connected lighting. The basic model offers three selectable operating modes: normal/stand-alone, externally controlled output and externally controlled output – 200 per cent.
For the last two, the lighting output is activated by an external signal and follows it. For the 200 per cent variant – which doubles the current/light intensity – the pulse duration at the output is limited to five seconds.
The product range includes models with up to four lighting outputs/channels, as well as control via Ethernet and RS232.
Housings made of black anodised aluminium
Contact options
Data sheet
Request for a quotation
Order information
| General specifications | |
|---|---|
| Supply voltage | 24 V DC ± 10 per cent, max. 2.5 A |
| Output power per channel | 15W / 45W (max. 1A / 3A) |
| Light intensity | Adjustable 0–100% |
| Trigger input | 5–24 V, optically isolated (does not apply to PAD21136/x & PAD21436/1) |
| Operating temperature | 0–55°C |
Order details |
|||||
|---|---|---|---|---|---|
| Order number | Intensity control | Outflow/channel | Number of channels | Externally controlled output | Installation and User Guides |
| PAD2 1135/1 | Internal potentiometer / 0–10 V 1 | 1 A | 1 | Yes | |
| PAD2 1135/3 | Internal potentiometer / 0–10 V 1 | 3 A | 1 | Yes | |
| PAD2 2135/1 | External dimmer | 1 A | 1 | Yes | Installation/User Guide |
| PAD2 2135/3 | External dimmer | 3 A | 1 | Yes | Installation/User Guide |
| PAD2 1235/1 | Internal potentiometer | 1 A/chan. | 2 | Yes | Installation/User Guide |
| PAD2 1235/3 | Internal potentiometer | 3 A/chan. | 2 | Yes | Installation/User Guide |
| PAD2 1435/1 2 | Internal potentiometer | 1 A/chan. | 4 | Yes | Installation/User Guide |
| PAD2 1136/1 | RS-232 | 1 A | 1 | – | Installation/User Guide |
| PAD2 1136/3 | RS-232 | 3 A | 1 | – | Installation/User Guide |
| PAD2 1436/1 | RS-232 | 1 A | 4 | – | Installation/User Guide |
| PAD2 4136/1 | Ethernet | 1 A | 1 | Yes | Installation/User Guide |
| PAD2 4136/3 | Ethernet | 3 A | 1 | Yes | Installation/User Guide |
| PAD2 4236/1 | Ethernet | 1 A | 2 | Yes | Installation/User Guide |
| PAD2 4236/3 | Ethernet | 3 A | 2 | Yes | Installation/User Guide |
| PAD2 4436/1 2 | Ethernet | 1 A | 4 | Yes | Installation/User Guide |
Cables must be ordered separately, specifying the item number and cable length. E.g. LKA1 1081/3
1 The LKA2 5135 extension cable is recommended.
2 Trigger cables are available as an option.